Dell 3348 Switch User Manual


 
322 Viewing Statistics
www.dell.com | support.dell.com
Click Statistics/RMON > RMON> Alarms in the Tree View. The RMON Alarm
page opens.
RMON Alarm Page
The RMON Alarm page contains the following fields:
Alarm Entry—Indicates a specific alarm.
Counter Name—Indicates the selected RMON counter.
Counter Value—Indicates the value of the RMON counter.
Sample Type—Specifies the sampling method for the selected variable and compares
the value against the thresholds. The possible field values are:
Delta—Subtracts the last sampled value from the current value. The difference in
the values is compared to the threshold.
Absolute—Compares the values directly with the thresholds at the end of the
sampling interval.
Rising Threshold—The rising counter value that triggers the rising threshold alarm.