Configuring the PowerConnect 3324/3348 Switch 45
Baud Rate
The baud rates can be manually changed to any of the following values:
• 2400
• 4800
• 9600
• 19,200
• 38,400
• 57,600
• 115,200
NOTE: The default baud rate is 9600.
NOTE: Closing the device does not return the default baud rate. It must be specifically
configured.
NOTE: In order to enter configuration mode, you must specify administrative level 15
privileges.
The following is an example configuration for changing the default baud rate using CLI
commands:
console> enable
console# configure
console(config)# line console
console(config-line)# speed 9600
console(config-if)# exit
console(config)# exit
Terminal Connection Configuration
The PowerConnect 3324/3348 requires the following Terminal Connection parameters for
configuration:
•no parity
• one stop bit
• 8 data bits