Extron electronic MPX PLUS 866 A Switch User Manual


 
4-19
MPX Plus 866 A Media Presentation Matrix Switcher • SIS Programming and Control
PRELIMINARY
Symbol definitions for IP SIS commands
X3)
= Matrix name (Up to 240 characters)
N
The following characters are invalid in the name: {space} ~ , @ = ` [ ] { } < > ‘ “ ; : \ | and ?.
X3!
= Default name Factory default name (model name + last 3 pairs of MAC address)
X3@
= Timeanddate(set) Intheformat:MM/DD/YY•HH:MM:SSwhere:
MM = month: 01 (January) through 12 (December)
DD = day: 01 through 31
YY=year:00through99
HH = hour: 00 through 24
MM = minutes: 00 through 59
SS = seconds: 00 through 59
X3#
= Timeanddate(read) Intheformat:Day,•DD•Mmm•YYYY•HH:MM:SSwhere
Day = weekday: Mon through Sun
DD = day: 01 through 31
Mmm = month: Jan through Dec
YYYY=year:2000through2099
HH = hour: 00 through 24
MM = minutes: 00 through 59
SS = seconds: 00 through 59
X3$
= GMToffset -12.0through+14.0(hoursandminutesremovedfromGMT)
X3%
= Daylight Savings Time 0 = Daylight Savings Time off/ignore
1 = Daylight Savings Time on (northern hemisphere)
2 = Daylight Savings Time on (Europe)
3 = Daylight Savings Time on (Brazil)
X3^
= IP address ###.###.###.###
X3&
= Hardware (MAC) address ##-##-##-##-##-##
X3*
= Number of open connections 0 - 255
X3(
= Password 12 alphanumeric characters
N
The following characters are invalid in passwords: {space} ~ , @ = ` [ ] { } < > ‘ “ ; : \ | and ?.
X4)
= Domain name Standard domain name conventions apply (for example, xxx.com)
N
The following characters are invalid in passwords: {space} ~ , = ` [ ] { } < > ‘ “ ; : \ | and ?
The @ character is only acceptable as the lead-in to the domain name (such as @extron.com).
X4^
= DHCP 0 = off, 1 = on
X4&
= Port # 01 = rear panel RS-232 Primary port
02 = rear panel RS-232 Secondary port/front panel Cofiguration port
N
The rear panel RS-232 Secondary port (
X4&
= 02) is active only if the front panel Configuration port is not in use. If a front panel
configuration connection is made, the rear panel RS-232 Secondary port becomes inactive and the front panel Configuration port is
active.
X4*
= Baud rate 9600, 19200, 38400, 115200
X4(
= Parity Odd, even, none, mark, space (only first letter required)
X5)
= Data bits 7, 8
X5!
= Stop bits 1, 2
X5@
= Port type 0 = RS-232 1 = RS-422
X5#
= Verbose mode 0 = Clear/none (default for Telnet connection
1 = Verbose mode (default for RS-232 connection)
2 = Tagged responses for queries
3 = Verbose mode and tagged for queries
N
If tagged responses is enabled, all read commands return the constant string and the value as the set command does (for example, the read
matrix name command,
E
CN
}
, returns IPN
•X3)]
).
X5$
= Security level 00 = Anonymous
10 = Extended security levels 1 through 10
11 = User
12 = Administrator
X5%
= RAM status 0 = RAM dirty (needs saving to flash)
1 = RAM has been saved (ok to power off / reset)
X5^
= Port timeout interval (in 10-sec. increments) 1 (= 10 seconds) – 65000 (default is 30 = 300 seconds = 5 minutes)