HP (Hewlett-Packard) HP 83206A Network Card User Manual


 
112
S:\HP83206A\USRGUIDE\MANUAL\meas.fm
Chapter 4, Making Measurements
Adjacent Channel Power
Adjacent Channel Power
Adjacent Channel Power is measured in either Connect state or test mode.The
measurement procedure described below is for the Connect state. To measure in
the test mode, see “Test mode measurement procedure” on page 118.
Adjacent Channel Power measures the power on six adjacent channels. These are
the three nearest channels both below and above the designated channel.
Adjacent Channel Power is measured on each adjacent channel relative to the
current channel.
Adjacent Channel Power measurement procedure
1. Make sure the Test Set is in Connect state. See
“Registration” on page 93.
2. Select
Meas
from the
Data/Meas
field.
3. A field appears below the
Data/Meas
field. Select this field.
4. Select
Adj Ch Pwr
from the list of choices. The Adjacent Channel Power will be
displayed. This measurement can take several seconds to complete.
Figure 35 Adjacent Channel Power Display
adjchpwr.tif