HP (Hewlett-Packard) HP 83206A Network Card User Manual


 
235
Chapter 7, Screen and Field Descriptions
Parameters of the ANALOG MEASUREMENT Screen
Screen and Field Descriptions
Detector Settings: RMS, RMS*SQRT2, PK+, PK-, Pk
±
/2, Pk±Max, Pk+ Hold, Pk±/2 Hold,
Pk±Mx Hold
Units: None.
This field is used to select the type of detector used to measure the amplitude of
the audio signal being measured.
Filter 1 Settings: <20Hz HPF, 50Hz HPF, 300Hz HPF, C MESSAGE
Units: None.
This field selects one of several standard or optional audio frequency filters which
can be used to condition the audio signal before being analyzed by the Audio
Frequency Analyzer.
Filter 2 Settings: 300Hz LPF, 3kHz LPF, 15kHz LPF, >99kHz LPF, 6kHz BPF
Units: None.
This field selects one of several standard or optional audio frequency filters which
can be used to condition the audio signal before being analyzed by the Audio
Frequency Analyzer.
FM Deviation This is a measurement
This field displays the measured FM deviation of the carrier being transmitted by
the mobile station. Four dashes (----) indicate that no carrier is present to measure.
TX Freq Error This is a measurement
This field displays the frequency error (error = assigned carrier frequency -
measured carrier frequency) of the carrier being transmitted by the mobile station.
Four dashes (----) indicates that there is no carrier frequency present to measure.
TX Power This is a measurement
This field displays the measured RF power of the carrier being transmitted by the
mobile station. Four dashes (----) indicates that there is no carrier present to
measure.