HP (Hewlett-Packard) HP 83206A Network Card User Manual


 
222
S:\HP83206A\USRGUIDE\MANUAL\ref.fm
Chapter 7, Screen and Field Descriptions
Parameters of the DCCH CALL CONFIGURE Screen
DCCH DVCC Settings: 0 through 255
Units: None.
This is the DVCC which applies to the DCCH only. For the DVCC of the DTC,
see “Parameters of the CALL CONTROL Screen” on page 208.
Dig Signal Settings: Std or NonStd
Units: None.
Dig Signal specifies if the received signal should conform to standard DCCH or
DAMPS protocol. NonStd causes the Cellular Adapter’s DSP to ignore protocol
discrepancies and only report an error condition if the signal level is too high.
DTC Burst Settings: Norm or Shorten
Units: None.
DTC Burst selects between a normal burst or shortened burst. The shortened burst
is usually transmitted as part of time alignment to help avoid collisions between
the mobile’s burst and the burst in an adjoining time slot.
Power Meter Settings: This is an action field. Selecting this field automatically zeros the power
meter within the Test Set.
Units: None.
PSID/RSID Settings: PSID or RSID, and 1 through 65,535
Units: None
Lists the private or residential systems and the associated system number for each
system. This field is only displayed if the value of the
# Systems field is 1.