Chapter 1, Getting Started
Get ready to test
Getting Started
Zeroing the
Average Power
Meter
TDMA Average Power can be measured if your Test Set is equipped with
Option 006, or if you have a PCS Interface connected. If you are not using the
PCS Interface, you need to zero the average power detector in the Test Set first
using the following procedure.
See “Average Power” on page 114 and “Power Measurements” on page 130 for
more information.
1. Disconnect all cables from the RF IN/OUT port of the Test Set.
2. Select
CALL CNTL
from the
To Screen
. (Use
MORE
to display the field
CALL
CNTL
.)
3. Select
DCCH
in the
System Type
field.
4. Select
CALL CNFG
from the
To Screen
.
5. Select
Zero
from the
Power Meter
field. This zeros the power for the Test System.
When the Test Set is finished zeroing, the
Zero
field is no longer highlighted.
6. Select
CALL CNTL
from the
To Screen
. This returns the Test Set to the primary call
processing screen.
Figure 3 Zeroing the Average Power Meter
CALL CNTL
CALL CNFG
More
System Type
Power Meter
CALL CNTL
dcch_cc.tif
Callcont.tif
rx-test.tif