Hitachi X200 Series Power Supply User Manual


 
List of Holding Registers
Network Data
Func.
Code
Name R/W Description
Reg. Range Res.
F002
(high)
R/W 1014h
F002
(low)
Acceleration (1) time
setting *1
R/W
Standard default acceleration,
range is 0.01 to 3000 sec.
1015h
1 to
300000
0.01 sec.
F202
(high)
R/W 1501h
F202
(low)
Acceleration (1) time
setting, 2nd motor *1
R/W
Standard default acceleration,
2nd motor, range is 0.01 to 3000
sec.
1502h
1 to
300000
0.01 sec.
F003
(high)
R/W 1016h
F003
(low)
Deceleration (1) time
setting *1
R/W
Standard default deceleration,
range is 0.01 to 3000 sec.
1017h
1 to
300000
0.01 sec.
F203
(high)
R/W 1503h
F203
(low)
Deceleration (1) time
setting, 2nd motor *1
R/W
Standard default deceleration,
2nd motor, range is 0.01 to 3000
sec.
1504h
1 to
300000
0.01 sec.
F004 Keypad Run key
routing
R/W Two options; select codes:
00...Forward
01...Reverse
1018h 0, 1
Note 1: When the value is 10000 (100.0 seconds), a value in the second decimal place
is ignored.
B24B24
Appendix B