Hitachi X200 Series Power Supply User Manual


 
List of Holding Registers
Network Data
Func.
Code
Name R/W Description
Reg. Range Res.
B133 DC bus AVR
selection
R/W Two option codes:
00Disabled
01Enabled
1176h 0, 1
B134 Threshold voltage of
DC bus AVR setting
R/W Setting of threshold voltage of DC bus
voltage to start DC bus AVR function.
Range is:
200V class330 to 395
400V class660 to 790
1177h 330 to 395,
660 to 790
1 V
B140 Over-current trip
suppression
R/W Two option codes:
00Disable
01Enable
10F7h 0, 1
B150 Carrier mode R/W Automatically reduces the carrier
frequency as the ambient temperature
increases.
00Disable
01Enable
10F8h 0, 1
B151 Selection of RDY
function
R/W Select Ready function.
00Disable
01Enable
10F9h 0, 1
Note 1: Assume that the inverter current rating is 10000 (for B013/B213).
B
35
Appendix B