92
Chapter 4 Emulation Menu
Select SFCC
This parameter allows you to select which ASCII codes will function as the
Special Function Control Code (SFCC) command delimiter. P-Series codes
can use hex 00 through hex 7F. Options include the following:
• ESC (hex 1B)
• SOH (hex 01)
• ETX (hex 03)
• CIRCUMFLEX (hex 5E)—also called caret (^)
• TILDE (hex 7E)—(~)
EVFU Select
Controls how the printer handles vertical formatting.
• Enable. Enables the VFU and selects P-Series compatible Electronic
Vertical Format Unit (EVFU).
• Disable. Disables VFU processing.
Alt. Set 80-9F
Determines whether the printer processes ASCII codes hex 80 through hex
9F as control codes or as printable characters.
Character Set
Specifies a character set as shown in the character set menu. To use one of
these sets, choose the desired group heading (such as Multinational) and
press ENTER. Then choose the desired set within that group (such as
EBCDIC) and press ENTER. Both the group and the desired set name will
include an asterisk to indicate your selection.
SFCC d Command
• Even dot plot. This option interprets SFCC d Command as even dot plot.
• Double high. This option interprets SFCC d Command as double high.
Select this option for backward compatibility.
Note SOH, ETX and ESC are non-printables. The characters (^) and (~) are
printable. However, do not use them as printables in the host data stream if
either is chosen as a delimiter, because print errors will occur.