Printronix P5000LJ Printer User Manual


 
98
Chapter 4 Emulation Menu
Auto LF
The Auto LF option defines the printer actions when print data is received past
the forms width setting.
Enable. Performs an automatic carriage return and line feed when data is
received past the forms width.
Disable. Discards any data past the forms width.
Overstrike
This option enables you to print bold characters.
Enable. Turns on bold print. When enabled, overstrike printing slows
down the printer.
Disable. Turns off bold print.
Define LF Code
LF = LF. Does not perform an automatic carriage return when a line feed
command is received. The next print position will be the current print
position of the next line.
LF = CR + LF. Forces an automatic carriage return with each line feed
command received. The next print position is print position 1 of the next
line.
Printer Select
Disable. Ignores the ASCII DC1 and DC3 control codes.
Enable. Disables the printer when a DC1 control code is received, and
enables the printer when a DC3 control code is received.
Alt. Set 80-9F
Control Code. Interprets data in the range of hex 80 through hex 9F as a
control code.
Printable. Prints data in the range of hex 80 through hex 9F.
Character Set
Specifies a character set as shown in the “Serial Matrix Character Set Menu”
on page 99. To use one of these sets, choose the desired group heading
(such as European Sets) and press ENTER. Then choose the desired set
within that group (such as Roman 8) and press ENTER. Both the group and
the desired set name will include an asterisk to indicate your selection.
Character sets are shown in detail in the Character Sets Reference Manual.
ESC d Command
Even dot plot. Interprets the ESC d command as even dot plot.
Double high. Interprets the ESC d Command as double high. Select this
option for backward compatibility.