Chapter 4 Emulation Menu
Auto LF
This option defines the printer actions when print data is received past the
forms width setting.
Enable. Performs an automatic carriage return and line feed when data is
received past the forms width.
Disable. Discards any data past the forms width.
Define LF Code
LF = LF. Does not perform an automatic carriage return when a line feed
command is received. The next print position will be the current print
position of the next line.
LF = CR + LF. Forces an automatic carriage return with each line feed
command received. The next print position is print position 1 of the next
line.
FF Valid at TOF
Enable. Performs a form feed when the host sends a Form Feed
command and the printer is at the top of form.
Disable. Will not perform a form feed when the host sends a Form Feed
command and the printer is at the top of form.
Character Set
Specifies a character set as shown in the menu. To use one of these sets,
choose the desired character set and press ENTER. The desired set will be
marked with an asterisk to indicate your selection.
Alt. Char Set
This option determines if data in the range of hex 80 through hex 9F should
be interpreted as a control code or as a printable character.
Set 1. Interprets data in the range of hex 80 through hex 9F as a control
code.
Set 2. Prints data for the characters at hex locations 03, 04, 05, 06, 15,
and 80 through 9F.
20 CPI Condensed
Condensed print characters are narrower than the normal character set. This
is helpful for applications for which you need to print the maximum amount of
information on a page.
Enable. Prints characters about 60 percent the width of normal
characters when condensed print is chosen by the host computer.
Disable. Does not condense print widths, even if condensed print is
chosen by the host.