M84Pro Service Manual PN: 9001111A Page 9-1
9
FACTORY RESETS
This section of the service manual covers instructions on how to return the printer to its factory
settings. The instructions are separated into differing categories of interest.
FACTORY SETTINGS / TEST PRINT
1 Record all dip switch positions.
2 Place all dip switches in the OFF position.
3 Place the DSW2-4 in the ON position.
4 Simultaneously, press and hold the LINE and FEED keys while turning on the power switch.
5 Release the LINE and FEED keys upon hearing a beep.
6 Place the DSW2-4 in the Off position.
7 Press the FEED key to display the next screen.
8 Press the LINE key once to change the message from NONE to ALL.
9 Press the FEED key to clear the EEPROM.
10 Select the print label size by pressing the LINE key.
CAUTION: RESETTING THE PRINTER WILL CLEAR ALL REGISTERS.
LCD DISPLAY: INITIALIZING ROM V00.00.00.00
MAINTENANCE MODE DIPSW2-4 ON->OFF
LCD DISPLAY: FACTORY MODE
LCD DISPLAY: COUNTER CLEAR - NONE
LCD DISPLAY: COUNTER CLEAR - ALL
LCD DISPLAY: PRINT SIZE
SMALL L
ARGE
NOTE: The default selection is large. The LINE key allows scrolling from one
option to another.