132 H9 ASD Installation and Operation Manual
Preset Speed 9
Program ⇒ Frequency ⇒ Preset Speeds
This parameter assigns an output frequency to binary number 1001 and is
identified as Preset Speed #9. The binary number is applied to S1 – S4 of the
Terminal Board to output the Preset Speed (see
F018 for more information on
this parameter).
Direct Access Number — F288
Parameter Type — Numerical
Factory Default — 0.0
Changeable During Run — Yes
Minimum — Lower Limit (F013)
Maximum — Upper Limit (F012)
Units — Hz
Preset Speed 10
Program ⇒ Frequency ⇒ Preset Speeds
This parameter assigns an output frequency to binary number 1010 and is
identified as Preset Speed #10. The binary number is applied to S1 – S4 of the
Terminal Board to output the Preset Speed (see
F018 for more information on
this parameter).
Direct Access Number — F289
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — Lower Limit (F013)
Maximum — Upper Limit (F012)
Units — Hz
Preset Speed 11
Program ⇒ Frequency ⇒ Preset Speeds
This parameter assigns an output frequency to binary number 1011 and is
identified as Preset Speed #11. The binary number is applied to S1 – S4 of the
Terminal Board to output the Preset Speed (see
F018 for more information on
this parameter).
Direct Access Number — F290
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — Lower Limit (F013)
Maximum — Upper Limit (F012)
Units — Hz
Preset Speed 12
Program ⇒ Frequency ⇒ Preset Speeds
This parameter assigns an output frequency to binary number 1100 and is
identified as Preset Speed #12. The binary number is applied to S1 – S4 of the
Terminal Board to output the Preset Speed (see
F018 for more information on
this parameter).
Direct Access Number — F291
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — Lower Limit (F013)
Maximum — Upper Limit (F012)
Units — Hz
Preset Speed 13
Program ⇒ Frequency ⇒ Preset Speeds
This parameter assigns an output frequency to binary number 1101 and is
identified as Preset Speed #13. The binary number is applied to S1 – S4 of the
Terminal Board to output the Preset Speed (see
F018 for more information on
this parameter).
Direct Access Number — F292
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — Lower Limit (F013)
Maximum — Upper Limit (F012)
Units — Hz
Preset Speed 14
Program ⇒ Frequency ⇒ Preset Speeds
This parameter assigns an output frequency to binary number 1110 and is
identified as Preset Speed #14. The binary number is applied to S1 – S4 of the
Terminal Board to output the Preset Speed (see
F018 for more information on
this parameter).
Direct Access Number — F293
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — Lower Limit (F013)
Maximum — Upper Limit (F012)
Units — Hz
F288 F293