Toshiba H9 Network Card User Manual


 
218 H9 ASD Installation and Operation Manual
Output Function Assigned
Program My Function My Function Unit 2
This parameter plays a role in the setup of the My Function feature by
selecting the functionality of the Output Function Assigned terminal.
This setting assigns the function of the programmable Output Function
Assigned data location to one of the functions listed in the Input Setting field
of
Table 8 on pg. 241.
Settings:
0 – 3099
See the My Function Instruction Manual (P/N 58692) and F977 for more
information on this parameter.
Direct Access Number — F911
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
Input Function Target 1
Program My Function My Function Unit 3
This parameter plays a role in the setup of the My Function feature by
selecting the functionality of the programmable Input Function Target 1
terminal.
This setting assigns the function of the programmable Input Function Target 1
terminal to any one of the user-selectable functions listed in
Table 7 on pg. 240,
Table 8 on pg. 241, or Table 10 on pg. 243.
See F977 for more information on this parameter.
Direct Access Number — F912
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
Input Function Command 1
Program My Function My Function Unit 3
This parameter is used to assign a user-selected logical operator to two user-
selected Input Function Target variables, enable a counter/timer function, or
perform a hold/reset function.
Table 11 on pg. 245 lists the available selections. Their use and selection
requirements are described in an example at F977.
Direct Access Number — F913
Parameter Type — Selection List
Factory Default — 0 (NOP)
Input Function Target 2
Program My Function My Function Unit 3
This parameter plays a role in the setup of the My Function feature by
selecting the functionality of the programmable Input Function Target 2
terminal.
This setting assigns the function of the programmable Input Function Target 2
terminal to any one of the user-selectable functions listed in
Table 7 on pg. 240,
Table 8 on pg. 241, or Table 10 on pg. 243.
See F977 for more information on this parameter.
Direct Access Number — F914
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
Input Function Command 2
Program My Function My Function Unit 3
This parameter is used to assign a user-selected logical operator to two user-
selected Input Function Target variables, enable a counter/timer function, or
perform a hold/reset function.
Table 11 on pg. 245 lists the available selections. Their use and selection
requirements are described in an example at F977.
Direct Access Number — F915
Parameter Type — Selection List
Factory Default — 0 (NOP)
F911 F915