34 H9 ASD Installation and Operation Manual
Keypad Remote Mounting w/o the ASD-MTG-KIT
Note: See Figure 25 for the dimensions and the item locations referenced in steps 1 through 5.
1. At the keypad mounting location, mark the 3.80” by 3.56” hole and the four 7/32” screw holes.
2. Cut the 3.80” by 3.56” rectangular hole.
3. Drill the four 7/32” screw holes.
4. Attach and secure the EOI to the front side of the mounting location using the four 6-32 x 5/16” pan
head screws, the #6 split lock washers, and the #6 flat washers.
5. Connect the extension cable.
Keypad Dimensions (mounting)
Figure 25. Keypad Mounting Dimensions.