75
Commands
Program Mode Commands
11/24/09 APL-I Reference Guide 14177L-003
Interpretive Field, Enable or Disable
Purpose To determine if the interpretive field of the current bar code field prints.
Syntax
in
Supported Based on testing, this command works the same on the Zebra printer with
APL-I firmware as on the 3400D printer.
Notes Use the I command when you want to edit an interpretive field. In the interpretive
field, the human-readable font prints 2 dots left aligned under the bar code.
Default: n = 0
Accepted values for n:
0 = disabled
1
= enable with start and stop characters
2
= enable without start and stop characters
Length of Line or Box Field, Define
Purpose To determine the length of a line or box.
Syntax
ln
Supported Based on testing, this command works the same on the Zebra printer with
APL-I firmware as on the 3400D printer.
Notes When in Advanced mode, a dot for a 200 dpi printer is 5 mil, and a dot for a 400 dpi
printer is 3.3 mil.
Default Value: n = 100
Accepted values for n: 1 – 9999
Line Field, Create or Edit
Purpose To edit or create a line field.
Syntax
Ln
Supported Based on testing, this command works the same on the Zebra printer with
APL-I firmware as on the 3400D printer.
Notes The name parameter is optional and can consist of 8 ASCII characters
Default Value: n = 0
Accepted values for n: 0 – 199