Maintenance
132 Avaya CMS Sun Fire V880 Computer Hardware Installation, Maintenance, and Troubleshooting
!
DANGER
:
DANGER: Be sure to turn the key switch to the Forced Off position before handling any
internal components. Otherwise, it is possible for a user to restart the
system remotely while you are working inside it. The Forced Off position is
the only key switch position that prevents an RSC user from restarting the
system.
7. Turn off the system monitor.
8. Turn off any external SCSI devices, starting with the device that is closest to the
system and working toward the farthest device.
9. Using the Target Address Switch on the back of the external tape drive, set the SCSI
ID to 4.
10. Connect the tape drive to the SCSI port on the SunSwift card or the Dual FastEthernet
and Dual SCSI card.
11. Connect the power cord from the tape drive to a power source.
12. Turn on any external SCSI devices, starting with the device that is farthest from the
system and working toward the system.
13. Turn on the system monitor.
14. Turn on the system. Do not put the keyswitch in the locked position.
As the system powers up, the power LED on the monitor flashes.
15. Press Stop+A simultaneously as soon as the monitor power LED lights steadily and
the Sun logo is displayed on the monitor.
The ok prompt is displayed.
16. Enter the following commands:
setenv auto-boot? false
reset-all
The system resets and displays the ok prompt.
17. Enter:
probe-scsi-all
This checks to see that the system recognizes the new tape drive. The resulting
display should list the new drive as Target 4. If the new drive is not listed, check for a
secure connection between the SCSI port and the new drive.