Avocent SPC420 Network Card User Manual


 
182 DSView 3 Software Installer/User Guide
Example: Cascade switch connection
In the following example, an AutoView 200 1 x 8 switch is connected to port one of a DSR1021
switch named dsr-1021-huntsville, using an IQ module with an EID of 520255-023FB7. Each port
of the AutoView 200 switch is connected to a different target device (520255-023FB701 through
520255-023FB708).
dsr-1021-huntsville(1)
520255-023FB7switch one (1)520255-023FB701
dsr-1021-huntsville(1)
520255-023FB7switch one (2)520255-023FB702
dsr-1021-huntsville(1)
520255-023FB7switch one (3)520255-023FB703
dsr-1021-huntsville(1)
520255-023FB7switch one (4)520255-023FB704
dsr-1021-huntsville(1)
520255-023FB7switch one (5)520255-023FB705
dsr-1021-huntsville(1)
520255-023FB7switch one (6)520255-023FB706
dsr-1021-huntsville(1)
520255-023FB7switch one (7)520255-023FB707
dsr-1021-huntsville(1)
520255-023FB7switch one (8)520255-023FB708
Example: Power device connection
In the following example, an Avocent SPC power device is connected to the SPC port of a
DSR1021 switch named dsr-1021-huntsville. SPC device outlet A1 is connected to target device
02-17-F2 SPC A1.
dsr-1021-huntsville(SPC)
02-17-F2 SPC (A1)02-17-F2 SPC A1
To display a connections window:
1. In a Units View window (see Accessing Units View windows on page 106) click on a unit
name. The Unit Overview window will open.
2. Click Connections in the side navigation bar.
If you selected a target device, the Target Device Connections window will open,
including all connections to the target device.
If you selected a managed appliance, the Appliance Connections window will open,
including all connections to the managed appliance.
3. (Optional) Click Table to view the connections as a table, or click Graphical to view the
connections as an illustration.
Renaming a managed appliance connection
To rename a managed appliance connection:
1. In a Units View window containing appliances (see Accessing Units View windows on
page 106), click on the appliance name.
2. Click Connections in the side navigation bar. The Appliance Connections window will open.