Cisco Systems MGX 8230 Network Router User Manual


 
5-7
Cisco MGX 8230 Edge Concentrator Installation and Configuration
Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001
Chapter 5 Configuring the MGX 8230 Shelf
MGX 8230 MGX to BPX Feeder
Procedure
At the MGX 8230 CLI prompt on the ASCII terminal:
Step 1 Enter the default login and password provided in the release notes.
The terminal displays the slot number of the MGX 8230 PXM you have logged into by default:
card number [1]:
Step 2 Press Return to enter the CLI of this MGX 8230 PXM.
At run-time, you could also enter the slot number of a service module or a standby MGX 8230 PXM. In
this case, the CLI prompt shows:
NODENAME.1.1.PXM.a>
where NODENAME shows that the node has no name; the slot number of the MGX 8230 PXM is 1; and
this MGX 8230 PXM is active. The general format of the CLI prompt is:
nodename.1.slot.cardtype.a>
where nodename is the name of the node; the shelf (node) number is always 1; slot is the card location;
cardtype identifies the card; and the card state is active (a) or standby (s).
Step 3 Display the cards in the system:
NODENAME.1.1.PXM.a> dspcds
Step 4 Display any IP addresses in the system:
NODENAME.1.1.PXM.a> dspifip
Step 5 Change any IP addresses as needed:
NODENAME.1.1.PXM.a> cnfifip <interface> <IP_Addr> <Net_Mask> [BrocastAddr]
where interface is a number: 26 is the Ethernet (LAN AUI) port, 28 is the maintenance port (SLIP), or
37 for the ATM IP address (feeder application only). Note that BrocastAddr applies to only the Ethernet
interface (number 26).
Note Check the Release Notes for any variations in how to configure IP addresses.
Step 6 Execute the cnfname command to assign a name to the MGX 8230:
UNKNOWN.1.1.PXM.a> cnfname <node name>
where node name is a case-sensitive name up to eight characters. For example:
UNKNOWN.1.1.PXM.a> cnfname cisco22
Step 7 Execute the cnftime command to specify the time on the MGX 8230:
cisco22.1.1.PXM.a> cnftime <hh:mm:ss>
where hh is the hour of the day in the range 124; mm is the minute of the hour in the range 160; and
ss is the number of seconds in the minute and has a range of 160.