Chapter 6 Card and Service Configuration
Configuring Frame Relay Service
addcon <port> <DLCI> <cir> <chan_type> <egress_service_type> [CAC] <controller_type>
<mastership> [connID] <controllerID>
port is the logical port number on the MGX-FRSM-2CT3 in the range 1256. On the
MGX-FRSM-2T3E3 and MGX-FRSM-HS2, the range is 12. (See addport step if necessary.)
DLCI is the DLCI number in the range 01023 (2CT3/2T3/2E3/HS2).
cir is the committed information rate in one of the following ranges:
for 2CT3, 11536000 bps; for 2T3, 144210000 bps; 2E3, 134010000 bps; and
for HS2, 151840000 bps.
chan_type specifies the type of connection: 1=NIW; 2=SIW-transparent mode;
3=SIW with translation; 4=FUNI; and 5=frame forwarding.
egress_service_type is a number that specifies the type of queue on the egress:
1=high priority; 2=real-time VBR, 3=nonreal-time VBR; 4=ABR; and 5=UBR.
CAC optionally enables connection admission control: 1=enable; 2=disable (default). With CAC
enabled, the system adds the resource consumption represented by adding the connection to the total
resources consumed on a logical port.
controller_type is the controller type for signaling connections: 1 (the default) specifies a PVC and
applies to PAR; 2 specifies a SPVC and applies to PNNI.
mastership indicates if this end of the connection is master or slave: 1=master, 2=slave.
connID is the connection identifier at the remote end. It appears in the syntax as an optional
parameter because it is mandatory only when you add the connection at the master end. See Rules
for Adding Connections at the beginning of this chapter. connID can have one the following
formats according to the slave endpoint:
Nodename.SlotNo.PortNo.DLCI
Nodename.SlotNo.PortNo.ControllerId.DLCI
Nodename.SlotNo.PortNo.VPI.VCI for ATM endpoint
controllerID is a number indicating the type of network control application:
1=PAR, 2=PNNI, 3=MPLS.
For AX-FRSM-8T1 and AX-FRSM-8E1:
addcon <port> <DLCI> <cir> <chan_type> [CAC] <controller_type> <mastership> <remoteConnID>
<serv_type>
port is the logical port number in the range 1192 for T1 or 1248 for E1. (See addport step if
necessary.)
DLCI is the DLCI number in the range 01023.
cir is the committed information rate in one of the following ranges:
for T1, 01536000 bps for T1; for E1, 02048000 bps.
chan_type specifies the type of connection: 1=NIW; 2=SIW-transparent mode;
3=SIW with translation; 4=FUNI; and 5=frame forwarding.
CAC optionally enables connection admission control: 1=enable; 2=disable (default).
controller_type is the controller type for signaling: 1=PVC (PAR), the default, 2=SPVC (PNNI).
mastership indicates if this end of the connection is master or slave: 1=master, 2=slave.