Cisco Systems MGX 8230 Network Router User Manual


 
6-18
Cisco MGX 8230 Edge Concentrator Installation and Configuration
Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001
Chapter 6 Card and Service Configuration
ATM Universal Service Module (AUSM)
Note To migrate between ForeSight ABR and TM 4.0 ABR, the connections must be manually
deleted and then re-added. This migration is not possible at run-time.
Step 2 To configure usage parameter control (UPC) for the connection (channel), use cnfupccbr, cnfupcvbr,
cnfupcrtvbr, cnfupcabr, or cnfupcubr. Use dspcons to obtain the channel number.
cnfupccbr <port.vpi.vci> <enable/disable> <pcr[0+1]> <cdvt[0+1]> <IngPcUtil> <EgSrvRate>
<EgPcUtil>
port number is in the range 18.
vpi has a value in the range 0255.
vci can be in the range 065535 for a VCC or * for a VPC.
Conn type is the connection type: 0=VCC, and non-0 is the local ID of a
VPC in the range 11000.
Service Type is the service type: 1=CBR, 2=VBR, 3=Standard ABR, 4=UBR,
5=rt-VBR, and 6=ForeSight ABR.
mastership is the mastership status of the endpoint: 1=master, and 2=slave.
The default is slave, so you actually do not need to type a 2.
Controller_Type is the optional controller specification: 1=PAR (the default}.
2=SPVC (PNNI).
connID is entered at only the master end and consists of the node name,
slot number, port number, vci, and vpi of the slave end.
port.vpi.vci identifies the connection.
enable/disable is the UPC enable: 1=disable, 2=enable.
pcr[0+1] is the peak cell rate. Without IMA, the range is as follows:
T1, 103622 cells per second
E1, 104528 cells per second
clear E1, 104830 cells per second
For IMA, multiply the line rate by the number of links.
cdvt[0+1] is the cell delay variation tolerance for cells with CLP=0 and
CLP=1. The range is 1250000 microseconds.
IngPcUtil is the percent utilization on the ingress. The range is 1127. The
default is 0.