Cisco Systems MGX 8230 Network Router User Manual


 
B-1
Cisco MGX 8230 Edge Concentrator Installation and Configuration
Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001
APPENDIX
B
Cable Specifications
This appendix contains details on the MGX 8230 cabling. It includes the following sections:
T3 Trunk Cabling
Frame Relay Cabling
DC Power Cabling
AC Power Cabling
Control and Clock Cabling
External Alarm Cabling
Note In all cable references, the transmit direction is away from the MGX 8230, and the receive direction
is toward the MGX 8230.
T3 Trunk Cabling
A trunk cable connects each T3 port on the BNC-2T3 back card to a T3 port on other equipment. See
Table B-1 and Table B-2 for details.
Table B-1 Trunk Cables
Cable Parameter Description
Type 75-ohm coax cable (RG-59 B/U for short runs, AT&T 734A for longer runs).
Two per T3 line (XMT and RCV).
Max. Length 450 feet maximum between the MGX 8230 and other equipment.
Connector Terminated in male BNC; Rx is received from trunk, Tx is transmitted to
trunk.
Table B-2 T3 Connector Pin Assignments
Connector Description
Rx BNC Receive T3 from trunk
Tx BNC Transmit T3 to trunk