Cisco Systems MGX 8230 Network Router User Manual


 
5-16
Cisco MGX 8230 Edge Concentrator Installation and Configuration
Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001
Chapter 5 Configuring the MGX 8230 Shelf
MGX 8230 MGX to BPX Feeder
Partitioning Resources on the Broadband Interface
Note in this release, since PAR is the network controller controlling the MGX 8230, there is no need to
configure resources.
Configuring the Line as a Feeder Trunk
A line connected to the MGX 8230 PXM line module can function as a feeder trunk. In addition to
configuring the use of the trunk at the MGX 8230, you must also configure the trunk at the far-end BPX.
To configure the trunk for the feeder application at the near-end:
Step 1 Open the Configure Card window.
Step 2 For the CATEGORY, select PAR Configuration.
Step 3 In the PAR Configuration window, select PAR Interface. In the PAR Interface window, the only
configurable column is the PAR Interface Type.
Step 4 For the logical interface type1 for the feeder trunkhold the left mouse button down in the PAR
Interface Type column for this logical interface. The choices are feedertrunk and routing trunk.
Step 5 Select feedertrunk, then click on the modify button at the bottom of the screen.
Step 6 Log in to the BPX at the other end of the feeder trunk and use the addshelf command to add the
MGX 8230 as a feeder.