Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide
NOTE: The controller operates with BA370 rack-mountable enclosures assigned
enclosure ID numbers 0, 2, and 3. You set these ID numbers using the PVA module.
Enclosure ID number 1, which houses devices at targets 4 through 7, is not
supported. Do not use device target ID numbers 4 through 7 in a storage
subsystem.
L—Designates the LUN of the device.
Place one space between the port number, target number, and the two-digit LUN
number when entering the PTL address. An example of a PTL address is shown in
Figure 3–11.
Figure 3–11. PTL Naming Convention
Figure 3–12 shows the addresses for each device in an extended configuration. Use
this figure along with “Configuration Rules,” page 2–2, to help you work with the
devices in your configuration.
CAUTION: Selecting SCSI-3 mode enables LUN 0 of each target for the
Command Console LUN (CCL) by all hosts. If the hosts access the CCL
simultaneously, unpredictable consequences can occur. In cases where
the CCL can be accessed through multiple paths and LUNs, systems
administrators of each host must not attempt to access the CCL simulta-
neously.
LUN 00 (leading zeros are not required)
Target 02 (leading zeros are not required)
Port 1
02 001