Compaq HSZ80 Network Card User Manual


 
2–24 Configuring an HSZ80 Array Controller
UPS Support
NOTE: By default, the controller expects to use an external cache battery (ECB) as
backup power to the cache module. You can instead choose to use an
uninterruptable power supply (UPS) to provide backup power in the event of a
primary power failure.
Use the following command:
SET THIS_CONTROLLER CACHE_UPS
If you are configuring dual-redundant controllers, also indicate that the other
controller’s power is supported by a UPS. Use the following command:
SET OTHER_CONTROLLER CACHE_UPS
The other controller inherits the cache UPS setting for this controller.
See “SET controller” in Chapter 5, “CLI Commands,” for details about setting the
UPS.
See Table 1–8 on page 1–23 and Table 1–9 on page 1–25 for information about cache
policies.