Compaq HSZ80 Network Card User Manual


 
5–67
Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide
LOCATE
Indicates the physical location of configured units, storagesets, and devices by
flashing the amber device fault LED on the front of the storage building block (SBB).
The device fault LED flashes once per second until turned off with the LOCATE
CANCEL command. The LOCATE command can also be used to test the LED itself.
The device fault LED on a failed device stays on continuously. When located, the
device fault LED on a good device flashes. The flashing LED helps to distinguish
between located devices and failed devices. The device fault LED on failed devices
stays on after the LOCATE CANCEL command is entered.
NOTE: LOCATE issued on a frontend controller will not locate devices hanging off a
backend controller.
Syntax
LOCATE parameter
Parameters
Only one of the following parameters may be entered with each LOCATE command.
ALL
Causes the green device fault LEDs of all configured devices to flash. You can also
specify ALL to test all of the LEDs at once. Enter LOCATE CANCEL to turn off the
LEDs.
CANCEL
Turns off all green device fault LEDs turned on with the LOCATE command.