Compaq HSZ80 Network Card User Manual


 
5–141
Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide
DT_SUPPORT
State:
RECONSTRUCTING
LOCAL DISK100 (member 0) is NORMAL
REMOTE DISK200 (member 1) is NORMALIZING 2% complete
LOCAL DISK300 (member 2) is NORMALIZING 0% complete
REMOTE DISK400 (member 3) is NORMALIZING 0% complete
Size: 8378028 blocks
This example shows the full information for a controller:
SHOW THIS_CONTROLLER FULL
Controller:
Not configured for dual-redundancy
Device port SCSI address 7
Time: NOT SET
Host port:
SCSI target(s) (0, 2, 4, 5)
Preferred target(s) (0, 2, 4)
TRANSFER_RATE_REQUESTED = 20MHZ
Host Functionality Mode = A
Command Console LUN is target 0, lun 4
Cache:
64 megabyte write cache, version 4
Cache is GOOD
Battery is GOOD
No unflushed data in cache
CACHE_FLUSH_TIMER = DEFAULT (10 seconds)
NOCACHE_UPS
Mirrored Cache:
64 megabyte write cache, version 4
Cache is GOOD
Battery is GOOD
No unflushed data in cache
Extended information:
Terminal speed 19200 baud, eight bit, no parity, 1 stop bit
Operation control: 00000001 Security state code: 75580
Configuration backup disabled