Example
The following example shows the commands you would use to create Stripe1, a three-
member striped mirrorset that comprises Mirr1, Mirr2, and Mirr3, each of which is a
two-member mirrorset:
ADD MIRRORSET MIRR1 DISK10000 DISK20000
ADD MIRRORSET MIRR2 DISK30000 DISK40000
ADD MIRRORSET MIRR3 DISK50000 DISK60000
ADD STRIPESET STRIPE1 MIRR1 MIRR2 MIRR3
INITIALIZE STRIPE1 CHUNKSIZE=DEFAULT
ADD UNIT D101 STRIPE1
SHOW STRIPE1
SHOW D101
Configuring a Single-Disk Unit
Use the following steps to use a single disk drive as a single-disk unit in your
subsystem:
1. Add the disk drive using the following syntax:
ADD DISK DISKnnnn ptl-location switch_value
Optionally, you can append Device switch values. If you do not specify switch values,
default values are applied. See “ADD DISK,” page 5–7, for valid switches and values.
2. Initialize the disk drive using the following syntax:
INITIALIZE DISKnnnn switch
3. Present the disk drive to the host by giving it a unit number the host can
recognize. Optionally, you can append Unit switch values. If you do not specify
switch values, default values are applied. Use the following syntax:
ADD UNIT unit-number DISKnnnn switch_value