2–6 Configuring an HSZ80 Array Controller
Follow these steps to configure a controller:
NOTE: This procedure has been written for first-time configuring. However, you
can adapt the procedure when you reconfigure the controllers. For replacing and
upgrading the controllers, see the
HSZ80 Array Controller ACS Version 8.3
Maintenance and Service Guide
.
1. Use the power-verification and addressing (PVA) module ID switch to set the
SCSI ID number for the BA370 rack-mountable enclosure.
See “Setting the PVA Module ID Switch,” page 2–25, for details about PVA switch
settings.
2. Remove the program card ESD cover, and insert the program card into the
controller. Replace the ESD cover.
3. Turn on the power to the enclosure or cabinet by turning on the ac input boxes.
4. Establish a local connection to the controller.
See “Establishing a Local Connection to the Controller,” page 2–26, for details about
creating a local connection.
5. Set the SCSI target ID numbers for the controller. Use the following commands:
SET THIS_CONTROLLER PORT_1_ID = (
n,n
)
or
SET THIS_CONTROLLER PORT_2_ID = (
n,n
)
See “Setting SCSI Target ID Numbers,” page 2–33, for details about valid SCSI target
ID numbers.