Compaq HSZ80 Network Card User Manual


 
2–14 Configuring an HSZ80 Array Controller
11. Set the time on the controller, which provides a baseline for replacing the
external battery, using the following command:
SET THIS_CONTROLLER TIME=DD-MMM-YYYY:HH:MM:SS
NOTE: All values are numbers, except for MMM, which uses the first three
letters of the month. When setting hours, minutes, and seconds—HH, MM,
and SS—you must use 24-hour time.
12. Set up the battery discharge timer:
a. Start Frutil using the following command:
RUN FRUTIL
Frutil displays the following:
Do you intend to replace this controller’s cache battery? Y/N
b. Enter Y(es).
Frutil displays a three-step procedure and prompts you to press return.
c. Press return.
13. Enter any other optional CLI commands for your configuration.
See the following section, “Optional Steps,” and Chapter 5, “CLI Commands.”
14. Display details about the controller you configured. Use the following command:
SHOW THIS_CONTROLLER FULL
See “SHOW” in Chapter 5, “CLI Commands.”
IMPORTANT: If you are using a PC or terminal with the maintenance port cable,
you must connect the SCSI bus cables in the desired configuration. See “Con-
necting in Transparent Failover Mode to the Host,” page 2–15,for more informa-
tion about configurations.