Compaq HSZ80 Network Card User Manual


 
4–17
Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide
Changing Switches for a Storageset or Device
You can optimize a storageset or device at any time by changing the switches that are
associated with it. See “Choosing Switches for Storagesets and Devices,” page 3–42,
for an explanation of the switches. Remember to update the storageset’s profile
(hardcopy) when you change its switches.
Displaying the Current Switches
To display the current switches for a storageset or a single disk, enter the following
command at a CLI prompt:
SHOW storageset-name or device-name FULL
Changing RAIDset and Mirrorset Switches
Use the SET storageset-name command to change the RAIDset and Mirrorset
switches associated with an existing storageset. For example, the following command
changes the replacement policy for RAIDset RAID1 to BEST_FIT:
SET RAID1 POLICY=BEST_FIT
Changing Device Switches
Use the SET command to change the device switches. For example, the following
command enables DISK10000 to be used in a non-StorageWorks’ environment:
SET DISK10000 TRANSPORTABLE
The TRANSPORTABLE switch cannot be changed for a disk if the disk is part of an
upper-level container. Additionally, the disk cannot be configured as a unit if it is to
be used as indicated in this example.