2–20 Configuring an HSZ80 Array Controller
11. Set up the battery discharge timer:
a. Start Frutil using the following command:
RUN FRUTIL
Frutil displays the following:
Do you intend to replace this controller’s cache battery? Y/N
b. Enter Y(es).
Frutil displays a three-step procedure and prompts you to press return.
c. Press return.
12. Enter any other optional CLI commands for your configuration.
See the following section, “Optional Steps,” and Chapter 5, “CLI Commands.”
13. Display details about the controller you configured. Use the following command:
SHOW THIS_CONTROLLER FULL
See “SHOW” in Chapter 5, “CLI Commands.”
IMPORTANT: If you are using a PC or terminal with the maintenance port cable,
you must connect the SCSI bus cables in the desired configuration. See “Con-
necting in Multiple-Bus Failover Mode to the Host,” page 2–21,for more informa-
tion about configurations.