Compaq HSZ80 Network Card User Manual


 
5–11
Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide
ADD MIRRORSET
Names a mirrorset and adds it to the controller configuration.
Syntax
ADD MIRRORSET mirrorset-name disk-name1 [disk-nameN]
Parameters
mirrorset-name
Assigns a name to the mirrorset. This is the name used with the ADD UNIT
command to identify the mirrorset as a host-addressable unit.
The mirrorset name must start with a letter (A through Z) and may consist of a
maximum of nine characters including letters A through Z, numbers 0 through 9,
periods (.), dashes (-), or underscores (_).
IMPORTANT: It is common to name a mirrorset MIRR
n
, where
n
is a sequentially
assigned, unique identifier. Other naming conventions are acceptable, but this
naming convention presents both the type of container and its unique identifier in
an intuitive manner.
disk-name1 [disk-nameN]
Identifies the disk drives making up the mirrorset. A mirrorset may contain one to six
disk drives.
Switches
COPY=FAST
COPY=NORMAL (Default)
Sets the speed at which the controller copies data to a new member from normal
mirrorset members when data is being mirrored to the storageset’s disk drives.