5–76 CLI Commands
In dual-redundant controller configurations, if both controllers can’t be shutdown,
then both controllers and their ECB chargers remain on.
Example
This example shows how to power off the disk units and the cabinet in 10 seconds:
POWEROFF SECONDS=10
BATTERY_OFF OVERRIDE_BAD_FLUSH Success Controller and units in the cabinet are
shutdown and the ECB is not powering the
cache module.
BATTERY_OFF OVERRIDE_BAD_FLUSH Failure Controller and units in the cabinet are
shutdown and the ECB is not powering the
cache module.
BATTERY_OFF NO_OVERRIDE_BAD_FLUSH Success Controller and units in the cabinet are
shutdown and the ECB is not powering the
cache module.
BATTERY_OFF NO_OVERRIDE_BAD_FLUSH Failure Nothing is shutdown, the ECB is powering
the cache module, and user is notified of a
bad flush.
Table 5–4 Poweroff Switch Settings (Continued)
Battery
Switch
Override Switch Flush
Results
Action