Compaq HSZ80 Network Card User Manual


 
4–29
Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide
Figure 4–3. Accessing Units with the Host Port’s SCSI ID Number
To assign the units to one host using SCSI ID numbers, yet restrict the other host’s
access, use the following syntax:
SET D100 DISABLE_ACCESS_PATH = ALL
SET D100 ENABLE_ACCESS_PATH = 7
SET D101 DISABLE_ACCESS_PATH = ALL
SET D101 ENABLE_ACCESS_PATH = 7
SET D102 DISABLE_ACCESS_PATH = ALL
SET D102 ENABLE_ACCESS_PATH = 6
SET D103 DISABLE_ACCESS_PATH = ALL
SET D103 ENABLE_ACCESS_PATH = 6
Host bus
Digital
UNIX
Sun
HSZ80
Port 1 Port 2
Controller
device bus
Controller
device bus
CXO6479A
D100 D102 D101 D103
SCSI ID 7 SCSI ID 6