Compaq HSZ80 Network Card User Manual


 
5–94 CLI Commands
CAUTION: Setting CACHE_UPS without having a UPS or similar backup
system in place may result in data loss if power is interrupted.
Specify NOCACHE_UPS to instruct the controller to perform regular cache battery
checks and evaluate the condition of the cache batteries.
Setting the CACHE_UPS switch for either controller sets the CACHE_UPS switch
for both controllers.
COMMAND_CONSOLE_LUN
NOCOMMAND_CONSOLE_LUN (Default)
Enable or disables the virtual LUN used with the StorageWorks Command Console.
When changed, the new setting for this switch takes effect immediately.
NOTE: This switch enables (COMMAND_CONSOLE_LUN) and disables
(NOCOMMAND_CONSOLE_LUN) the CCL in SCSI-2 mode only. This switch has no
effect in SCSI-3 mode.
Select COMMAND_CONSOLE_LUN to enable the virtual LUN. Select
NOCOMMAND_CONSOLE_LUN to disable the virtual LUN.
HOST_FUNCTION=mode
HOST_FUNCTION=(ID,mode)
Configures the host compatibility mode for a controller target ID number. When
changed, you must restart both controllers in order for the new setting to take effect.
Select the HOST_FUNCTION=mode switch to set all of the targets on the host
interface to the same mode. The default mode is A.
Select the HOST_FUNCTION=(ID,mode) switch to configure the host port on a
target-by-target basis for compatibility with various operating systems.