Compaq HSZ80 Network Card User Manual


 
4–38 Configuring Storagesets
(...move disk drives to their new location...)
ADD DISK DISK20000 2 0 0
ADD DISK DISK30000 3 0 0
ADD DISK DISK40000 4 0 0
ADD RAIDSET RAID99 DISK20000 DISK30000 DISK40000
ADD UNIT D100 RAID99
Example
The following example shows the commands you would use to move the reduced
RAIDset, R3, to another cabinet. R3 used to contain DISK20000, which failed before
the RAIDset was moved. R3 contained DISK10000, DISK30000, and DISK40000 at
the beginning of this example.
DELETE D100
DELETE R3
DELETE DISK10000
DELETE DISK30000
DELETE DISK40000
(...move disk drives to their new location...)
ADD DISK DISK10000 1 0 0
ADD DISK DISK30000 3 0 0
ADD DISK DISK40000 4 0 0
ADD RAIDSET R3 DISK10000 DISK30000 DISK40000 REDUCED
ADD UNIT D100 R3