Dell DR715 Server User Manual


 
20 About Your System
E1211 ROMB Batt RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Reseat the RAID battery
connector (see "Installing
a RAID Battery" on
page 115, and
"Troubleshooting System
Cooling Problems" on
page 172).
E1214
E1216
E1217
##
PwrGd Specified voltage regulator
has failed.
See "Getting Help" on
page 205.
E121A 8V PwrGd 8V voltage regulator has
failed.
Recycle power to the
system or clear the SEL. If
the problem persists, see
"Getting Help" on
page 205.
E121D 1.2V VM Dual
PwrGd
1.2V voltage regulator for
the VM dual signal has
failed.
Recycle power to the
system or clear the SEL. If
the problem persists, see
"Getting Help" on
page 205.
E1227 Linear PwrGd Linear voltage regulator(s)
has failed. Represents status
of multiple voltage
regulators used in the video
and LOM circuitry.
See "Getting Help" on
page 205.
E1229 CPU # VCORE Processor # VCORE voltage
regulator has failed.
See "Getting Help" on
page 205.
E122A CPU VTT PwrGd Processor # VTT voltage has
exceeded the allowable
voltage range.
See "Getting Help" on
page 205.
E122D CPU # VDDIO
1.0V PwrGd
Processor # VDDIO voltage
has exceeded the allowable
voltage range.
See "Getting Help" on
page 205.
Table 1-5. LCD Status Messages (continued)
Code Text Causes Corrective Actions