Dell DR715 Server User Manual


 
30 About Your System
E201F DRAC Config Dell remote access
controller (DRAC)
configuration failure.
Check screen for specific
error messages.
Ensure that DRAC cables
and connectors are
properly seated. If
problem persists, see your
DRAC documentation.
E2020 CPU Config Processor configuration
failure.
Check screen for specific
error messages.
E2021 Memory
Population
Incorrect memory
configuration. Memory
population order incorrect.
Check screen for specific
error messages (see
"Troubleshooting System
Memory" on page 174).
E2022 POST Fail General failure after video. Check screen for specific
error messages.
E2110 MBE DIMM # &
#
One of the DIMMs in the
set implicated by "# & #"
has had a memory multi-bit
error (MBE).
See "Troubleshooting
System Memory" on
page 174.
E2111 SBE Log
Disable DIMM
#
The system BIOS has
disabled memory single-bit
error (SBE) logging, and will
not resume logging further
SBEs until the system is
restarted. "#" represents the
DIMM implicated by the
BIOS.
See "Troubleshooting
System Memory" on
page 174.
E2112 Mem Spare
DIMM #
The system BIOS has spared
the memory because it has
determined that the
memory had too many
errors. "# & #" represents
the DIMM pair implicated
by the BIOS.
See "Troubleshooting
System Memory" on
page 174.
Table 1-5. LCD Status Messages (continued)
Code Text Causes Corrective Actions