Dell DR715 Server User Manual


 
About Your System 27
E1811 HDD ## Rbld
Abrt
The specified hard drive has
experienced a rebuild abort.
See "Troubleshooting a
Hard Drive" on page 181.
If the problem persists,
see your RAID
documentation.
E1812 HDD ##
Removed
The specified hard drive has
been removed from the
system.
Information only.
E1914 DRAC5 Conn2
Cbl
DRAC 5 cable is missing or
disconnected.
Reconnect the cable (see
"Installing a RAC Card"
on page 119).
E1915 IO55 HTSink
Missing
MCP55 Htsink
Missing
Heat sink sensor reports that
the chipset IO55 heat sink is
missing.
Heat sink sensor reports that
the chipset MCP heat sink is
missing.
See "Getting Help" on
page 205.
E1A14 SAS Cable A SAS cable A is missing or
bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 205.
E1A15 SAS Cable B SAS cable B is missing or
bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 205.
E1A15 SAS Cable C SAS cable C is missing or
bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 205.
Table 1-5. LCD Status Messages (continued)
Code Text Causes Corrective Actions