Dell DR715 Server User Manual


 
24 About Your System
E141F CPU Protocol The system BIOS has
reported a processor
protocol error.
See "Getting Help" on
page 205.
E1421 CPU Init The system BIOS has
reported a processor
initialization error.
See "Getting Help" on
page 205.
E1422 CPU Machine
Chk
The system BIOS has
reported a machine check
error.
See "Getting Help" on
page 205.
E1610 PS # Missing No power is available from
the specified power supply;
specified power supply is
improperly installed or
faulty.
See "Troubleshooting
Redundant Power
Supplies" on page 171.
E1614 PS # Status No power is available from
the specified power supply;
specified power supply is
improperly installed or
faulty.
See "Troubleshooting
Redundant Power
Supplies" on page 171.
E1618 PS #
Predictive
Power supply voltage is out
of acceptable range;
specified power supply is
improperly installed or
faulty.
See "Troubleshooting
Redundant Power
Supplies" on page 171.
E161C PS # Input
Lost
Power source for specified
power supply is unavailable,
or out of acceptable range.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting
Redundant Power
Supplies" on page 171.
Table 1-5. LCD Status Messages (continued)
Code Text Causes Corrective Actions