3.2.6.10 Platen Removal
Step 1: Remove the paper bail assembly. (Refer to Section 3.2.6.7.)
Step 2: Remove the upper paper guide. (Refer to Section 3.2.6.8.)
Step 3: Remove the four hexagon socket screws securing the platen to the platen holders. Then remove
the platen with the lower paper guide composed of 3 parts in it.
Step 4: Slide the 3 parts of the lower paper guide to release the notches and remove them one by one
from the platen.
H exagon Socket Screw
Platen
Platen Holder (Left)
Platen Holder (R ight)
Low er Paper G uide
R ear
Figure 3-62. Platen Removal
Platen
Platen Holder
Positionning Tab
0 .0 3 m m
Thickness G auge
Front
R ear
No through
Figure 3-63. Platen Positioning
ASSEMBLING POINT
When you attach the 3 parts of the lower paper guide to the platen, start with the one at the right end
and work toward the left.
When you mount the platen to the platen holders, space between the platen and positioning tab on
the both sides must be less than 0.03mm. (Refer to Figure 3-63.)
ADJUSTMENT REQUIRED
When you install the platen, perform the following adjustments:
Carriage guide shaft parallelism adjustment (described in Section 4.1.5 and Section 4.1.6)
Platen angle (right angle) adjustment (described in Section 4.1.6)
Platen gap motor value (platen gap) adjustment (described in Section 4.1.7)