Intel MPCMM0001 Network Card User Manual


 
106 MPCMM0001 Chassis Management Module Software Technical Product Specification
Health Events
Timestamp is in the format: [Day] [Month] [Date] [HH:MM:SS] [Year]. For example,
Thu Dec 11 22:20:03 2003
ChassisLocation is the chassis location information recorded in the chassis FRU.
ChassisSN is the chassis serial number records in the chassis FRU.
Location is the location where the sensor generating the event is located (i.e., CMM)
SDR Sensor Name is the name given to the sensor in the Sensor Data Record (SDR).
Health Event Strings are listed in Section 11.4, “List of Possible Health Event Strings” on
page 108.
Event Type is either “Assertion Event” or “Deassertion Event” stating whether it is an event
that is being asserted or one that is being deasserted. This is not applied to threshold-based
sensor events since the string already states event type.
Event Code is a code unique to that event. The codes for each event can be found below in
Table 11.4, “List of Possible Health Event Strings” on page 108.
11.2 Sensor Targets
Available sensors for a location can be retrieved with the listtargets dataitem argument of the
cmmget command. To view a list of sensor targets on the cmm using the listtargets command:
cmmget -l cmm -d listtargets
List of targets for the CMM can be found in Table 19, “Remote Procedure Calls (RPC)” on
page 174.
For complete lists of sensors on other components (i.e., voltage sensors on blade1), refer to the
corresponding Technical Product Specification for that product.
Table 33. Sensor Targets (Sheet 1 of 2)
Sensor Target Description
Brd Temp Board Temperature Sensor
CPU Temp CPU Temperature Sensor
FilterTrayTemp [1/2] Filter Tray Temperature Sensor
CPU Core V CPU Core Voltage Sensor
VBAT Battery Sensor
VTT DDR VTT Sensor
+2.5V +2.5 Volt Sensor
+3.3V +3.3 Volt Sensor
+5V +5 V olt Sensor
+12V +12 Volt Sensor
CDM [1/2] CDM 1 or 2 Sensor