MPCMM0001 Chassis Management Module Software Technical Product Specification 149
SNMP
Table 64. CmmTable/cmmEntry (1.3.6.1.4.1.343.2.14.2.10.3.51.1) (Sheet 1 of 2)
OID Object Syntax Access Value
1 cmmTarget DisplayString none index
2 cmmCurrent DisplayString read-only The current value of a sensor.
3 cmmThresholdsAll DisplayString read-only All thresholds of a sensor.
4 cmmUpperCritical DisplayString read-only Upper critical thresholds
5 cmmUpperNonCritical DisplayString read-only upper non-critical thresholds
6 cmmLowerNonCritical DisplayString read-only lower non-critical thresholds
7 cmmLowerCritical DisplayString read-only lower critical thresholds
8 cmmUpperNonRecoverable DisplayString read-only upper non recoverable thresholds
9 cmmLowerNonRecoverable DisplayString read-only lower non recoverable thresholds
10
cmmMaximumExternalAvaila
bleCurrent
DisplayString read-write Each unit is 100mA
11
cmmMaximumInternalAvailabl
eCurrent
DisplayString read-only Each unit is 100mA
12
cmmMinimumExpectedOpera
tingVoltage
DisplayString read-write Each unit is 0.5 Volt
13 cmmSensorHealth INTEGER read-only
Health information about a particular
location/sensor. This will be one of the
following: (0-OK, 1-Minor, 2-Major, 3-
Critical)
14 cmmSensorHealthEvents DisplayString read-only
Events that contribute to the health of
the location/sensor. This is a list of
events happening on the location.
15 cmmMinorAction
OCTET
STRING
read-write
Used to configure user defined actions
when minor events occur.
16 cmmMajorAction
OCTET
STRING
read-write
Used to configure user defined actions
when major events occur.
17 cmmCriticalAction
OCTET
STRING
read-write
Used to configure user defined actions
when critical events occur.
18 cmmNormalAction
OCTET
STRING
read-write
Used to configure user defined actions
when normal events occur.
35 cmmfruBoardDescription DisplayString read-only
Used to read the Board Description
from the FRU.
36 cmmfruBoardManufacturer DisplayString read-only
Used to read the Board Manufacturer
from the FRU.
37 cmmfruBoardPartNumber DisplayString read-only
Used to read the Board Part Number
from the FRU.
38 cmmfruBoardSerialNumber DisplayString read-only
Used to read the Board Serial Number
from the FRU.
39
cmmfruBoardManufactureDat
e
DisplayString read-only
Used to read the Board Manufacture
Date from the FRU.
40 cmmfruProductDescription DisplayString read-only
Used to read the Product Description
from the FRU.
41 cmmfruProductManufacturer DisplayString read-only
Used to read the Product Manufacturer
from the FRU.
42 cmmfruProductPartNumber DisplayString read-only
Used to read the Product Part Number
from the FRU.