Intel MPCMM0001 Network Card User Manual


 
MPCMM0001 Chassis Management Module Software Technical Product Specification 83
The Command Line Interface (CLI)
powerstate
Retrieves and sets power
state of a blade.
Get: This is used to find out
the powered on/off or offline
state of a blade
Set: To reboot, shutdown and
turn on a blade
If “reset” is used on CMM
location, the software will
check for redundancy and a
reset will only occur if a
redundant partner is
identified.
“PowerOff” is not supported
on the CMM location.
Both
"<location>: <currentState> (Mx)"
where Mx is the ATCA-defined M state of
the location
"Reset"
"PowerOff"
"PowerOn"
presence
Used to find out if a particular
location is occupied or
present in the chassis. This
can be blades or intelligent
entities like fan trays or
PEMs.
Get
"<location> is <presenceState>."
Where <presenceState> is
"present" - if the location is present
"not present" - if the location is not
present or the CMM can not
communicate with it.
N/A
presentpowerlevel
Get/Set the current power
level of a FRU.
Get
"The FRU Power Level is <PwrLevel>
Consuming <WattageValue> Watts"
where
<PwrLevel> is the current power level of
the FRU in the range 1-20
<WattageValue> is the current power
draw in watts
N/A
sel
Returns the System Event
Log of the specified location.
Get
Listing of the interpreted SEL log of the
location. The listing is of the format:
“<Entry1>\n\n<Entry2>…”
where <EntryM> is of the format:
<Timestamp in Linux date
format>\n\t<SensorName>\t<EventDescr
iption>
N/A
grantedboardekeys
Get the EKeys that have
been granted to the Board.
Get
Base Interface Ekeys:
<EkeyList>
Fabric Interface EKeys:
<EkeyList>
Update Channel Interface EKeys:
<EkeyList>"
where <EkeyList> is a list of ekey
settings for the interface such as
Ekey1 : enabled
EKey2 : disbaled
EKey3 : no set
N/A
Table 25. Dataitem Keywords for All Locations Except Chassis and System (Sheet 3 of 4)
Dataitem Description Get/Set CLI Get Output Valid Set Values