Intel MPCMM0001 Network Card User Manual


 
84 MPCMM0001 Chassis Management Module Software Technical Product Specification
The Command Line Interface (CLI)
busedekeys
Get a list of Bused EKeys
and who owns them.
Get
Metallic Test Bus Pair #1:
Token Owned: Yes/No
Owner's IPMBAddress: IPMBAddress
Metallic Test Bus Pair #2:
Token Owned: Yes/No
Owner's IPMBAddress: IPMBAddress
Sync Clock Group #1:
Token Owned: Yes/No
Owner's IPMBAddress: IPMBAddress
Sync Clock Group #2:
Token Owned: Yes/No
Owner's IPMBAddress: IPMBAddress
Sync Clock Group #3:
Token Owned: Yes/No
Owner's IPMBAddress: IPMBAddress
where "Owner's IPMBAddress" is
displayed when "Token Owned" is set to
"Yes".
N/A
totalfrus
Used to query the total
number of FRUs in a
particular location. Once the
number of FRUs for the
location is known, the FRU
can be specified by the
format "-l location:fru#". Not
specifying the ":fru#" part will
direct the command to FRU
ID 0
Get integer number N/A
frudeactivationpolicy
Get/Set the deactivation
policy of the FRU. In PICMG
3.0 ECN 1 this refers to the
deactivation locked bit. The
FRU can be specified by the
format “-l [location:fru#]. Not
specifying the “:fru#” will
direct the command to FRU
0.
Both
1 - Locked bit is set
0 - Locked bit is not set
1- Set the locked
bit
0 - Clear the
locked bit
ipmicommand Set
Command Response string on success
or error code on failure.
Command request
string
rawsel
Used to list SEL in raw
format.
Get
"Listing of raw format SEL log of the
location. The listing is of the format:
<Entry1>\n\n<Entry2>…
Where :
<EntryM> is of the format: <Timestamp in
Linux date
format>\n\t<SensorName>\t<EventDescr
iption>"
N/A
Table 25. Dataitem Keywords for All Locations Except Chassis and System (Sheet 4 of 4)
Dataitem Description Get/Set CLI Get Output Valid Set Values