Intel MPCMM0001 Network Card User Manual


 
MPCMM0001 Chassis Management Module Software Technical Product Specification 89
The Command Line Interface (CLI)
snmpenable
Used to set or query SNMP
trap enabled status.
Both SNMP traps are <enabled/disabled>.
1=Enable
0=Disable
enable
disable
snmptrapaddress[1-5]
Get or Set the machine’s IP
address that will receive
SNMP traps from a location.
Up to five addresses can be
set. Default is 0.0.0.0 for all 5.
Example:
cmmset -l cmm -d
snmptrapaddress3 -v
10.10.241.105
Both
"SNMP trap address: IpAddress"
where IpAddress is of the format
A.B.C.D
<IpAddress>
Where:
<IpAddress> is a
Valid IP address in
the form: A.B.C.D
snmptrapcommunity
Get or Set the SNMP trap
community name.
Example:
cmmget -l cmm -d
snmptrapcommunity
Returns:
SNMP trap community:
publiccmm
Both
"SNMP trap community:
communityValue"
<CommunityName
>
Where
<CommunityName
> is any Valid
SNMP community
name 64 characters
or less. Ex:
publiccmm
snmptrapport
Get or Set the TCP/IP port that
the SNMP trap will be sent to.
The default is 162.
Both "SNMP trap port: portNumber"
Valid port number
0-65535
snmptrapversion
Retrieves or sets SNMP trap
version. This is either v1 or v3.
Both "SNMP trap version: v1/v3" “v1” or “v3”
airfilterruntimelimit
Returns the uppercritical limit.
Note: It uses the sensor to
display the runtime value in
days since the last reset.
To retrieve the
uppernoncritical limit use the
command:
cmmget -t "filter run time" -d
uppernoncritical
(or -d thresholdsall)
Both <uppercritical limit> Days
1. Disable eventing
on air filter run time
-v 0
2. Enable eventing
on air filter and set
the uppercritical
limit to (xxx) days,
and it also sets the
upper non-critical
value to 90% of the
uppercritical.
-v xxx
3. Enable eventing
on air filter and set
the uppercritical
limit to (xxx) days
and the upper non-
critical to (yyy) days
-v xxx,yyy
xxx and yyy must
be an integer
between 1 and 255.
resetairfilterruntime
Resets the air filter runtime to
0. The set is supported to
allow the user to set the run
time to zero when the filter is
replaced.
Set N/A
1 - Only accepts a
value of 1
Table 27. Dataitem Keywords for Cmm Location (Sheet 4 of 7)
dataitem Description
Get/
Set
CLI Get Output Valid Set Values