MPCMM0001 Chassis Management Module Software Technical Product Specification 87
The Command Line Interface (CLI)
alarmcutoff
Retrieve or set the state of the
Telco Alarm cutoff. When
enabled, it silences the Telco
alarm for active events and
blinks the event LEDs on the
CMM. This dataitem is only
valid when used with the cmm
as the location and is used to
set the alarm cutoff or get its
value.
Both
"Telco Alarm Cutoff is <enabled/
disabled>."
1 = Set cut off
0 = Unset cut off
alarmtimeout
Retrieve or set the timeout
value in minutes for the Telco
Alarm cutoff. This is the
amount of time before the
alarm cutoff will automatically
become unset if the user
doesn’t unset it themselves.
This dataitem is only valid
when used with the cmm as
the location and is used to set
the alarm timeout or get its
value.
Both "Timeout is <timeoutvalue> minutes."
Number of minutes:
0-1000.
Value of 0 disables
the time-out.
criticalled
minorled
majorled
Used only with the CMM
location to turn on or off the
critical, major and minor leds.
When used with cmmset, a –v
value of 1 turns the LED on
while a 0 turns it off.
Both
"1" if the LED is On
"0" if the LED is Off
1 - Turn On LED
0 - Turn Off LED
Ethernet
Included for backward
compatibility only.
The mapping of the command
for existing dataitem is:
Ethernet = EthernetA
Both
"front" or "rear" or "backplane"
For example,
bash-2.04# cmmget -d ethernet
cmm1ethernetA: front
cmm2ethernetA: front
"Front" – Set
direction to the front
panel.
"Back" – Set
direction to the rear
IO panel card.
EthernetA
EthernetB
Used only with the CMM
location to change the eth0/
eth1 direction to either the
front panel, the rear panel IO
card, or backplane.
The mapping of the command
for existing dataitems are:
EthernetA = cmm1EthernetA
+ cmm2EthernetA
EthernetB = cmm1EthernetB
+ cmm2EthernetB
Both
"Front" or "Rear" or "Backplane". For
example,
bash-2.04# cmmget -d ethernetA
cmm1ethernetA: front
cmm2ethernetA: front
bash-2.04# cmmget -d ethernetB
cmm1ethernetB: front
cmm2ethernetB: front
"Front", "Rear", or
"Backplane"
Table 27. Dataitem Keywords for Cmm Location (Sheet 2 of 7)
dataitem Description
Get/
Set
CLI Get Output Valid Set Values