Intel MPCMM0001 Network Card User Manual


 
MPCMM0001 Chassis Management Module Software Technical Product Specification 97
The Command Line Interface (CLI)
8.4.6 Value Parameter: -v
The value parameter specifies the new value for a dataitem. This parameter is required for all
cmmset commands and is only used for cmmset commands. Valid value parameters are shown
in with their corresponding dataitems in the data item tables listed above.
8.4.7 Sample CLI Operations
Sample CLI Operations can be found in Appendix A, “Example CLI Commands”.
8.5 Generating a System Status Report
The CLI includes an executable script (cmmdump) that is used to generate a system status report
for use in communicating system health and configuration information to technical support
personnel. This is useful in helping technical support successfully troubleshoot any issues that may
be affecting the system. Cmmdump outputs system information to the screen by default or to a file.
To send the output to a file use the following command:
cmmdump > [filename]
maxexternalavailable
current
Get/Set the field in the CDM
regarding the max external
available current. Only used
with the feedN target.
e.g.
cmmget -l cmm -t feed1 -d
maxexternalavailablecurrent
See Section 7.7, “Power Feed
Targets” on page 69.
Both current in Amps with 1 decimal point
current in Amps with
1 decimal point.
maxinternalcurrent
Get the field in the CDM
regarding the max internal
available current. Only used
with the feedN target.
e.g.
cmmget -l cmm -t feed1 -d
maxinternalcurrent
See Section 7.7, “Power Feed
Targets” on page 69.
Get current in Amps with 1 decimal point N/A
minexpectedoperating
voltage
Get/Set the field in the CDM
regarding the max expected
operating voltage. Only used
with the feedN target.
e.g.
cmmget -l cmm -t feed1 -d
minexpectedoperatingvoltage
See Section 7.7, “Power Feed
Targets” on page 69.
Both
voltage value in string between -36
to -72v
voltage value in
string between -36
to -72v
Table 30. Dataitem Keywords Used with the Target Parameter (Sheet 4 of 4)
dataitem Description
Get/
Set
CLI Get Output Valid Set Values